Micro modules | |||||||||||||||||
| appliance modules | lamp modules | shutter modules | ||||||||||||||||
| AW12 | AWM2P | TWM4 | LW12 | LWM1 | SW12 | SWM1P | ||||||||||||
| Application | Switching devices and lighting |
switching and dimming lighting |
operating sunblinds |
|||||||||||||||
| Load allowed at 230V ± 10% |
||||||||||||||||||
| Resistitive Load | 3600W | 2300W | - | - | - | |||||||||||||
| Incandescent light | 2000W | 2300W | - | 60 to 250W | 120W | - | ||||||||||||
| Inuctive/capacitive | 600W | 500W | - | - | 700W | 500W | ||||||||||||
| Low voltage halogen lighting with transformer | 2000W | 500W | - | 60 to 250W | 100W | - | ||||||||||||
| Characteristics | ||||||||||||||||||
| Number of usable X-10 addresses |
1 | 2 | 4 | 1 | 1 | 2 | ||||||||||||
| X-10 communication | One-way | Two-way | One-way | Two-way | One-way | Two-way | ||||||||||||
| Sendable X-10 commands | - | On/Off, Status |
On/Off, Dim+/Dim-, All Lights ON, All Lights OFF, All Units OFF, Status, Extended |
- | On/Off, Dim+/Dim-, Status, Extended |
- | On/Off, Status, Extended |
|||||||||||
| Receivable X-10 commands | On/Off | On/Off,
All Units Off, All Lights On, Status request |
On/Off,
Dim+/Dim-, All Lights ON, All Lights OFF, All Units OFF, Status request, Extended |
On/Off, Dim+/Dim- Extended |
On/Off, Dim+/Dim-, Status request Extended |
On/Off, Dim+/Dim-, Extended |
On/Off, Dim+/Dim-, Status request, Extended |
|||||||||||
| Memory | Status | - | Status, last dimming position |
Preset function | ||||||||||||||
| Soft start/Soft dim | - | Yes | - | |||||||||||||||
| Local blocking mode | - | - | No | Yes | ||||||||||||||
| Load directly connectable to the module | Yes | - | Yes | Yes | ||||||||||||||
| Silent Relays | - | Yes | - | - | Yes | |||||||||||||
| Application in 3 phase installation | Active phase coupler required | phase coupler required | phase coupler required | Active phase coupler required | phase coupler required | Active phase coupler required | ||||||||||||
| Connectable switches | Switch or Momentary switch | Momentary switch | Momentary switch | |||||||||||||||
| Local operation | Phase controlled | Neutral controlled | Phase controlled | Neutral controlled | Phase controlled | |||||||||||||
| Dimensions (mm) | 46x46x16 | 46x46x16 | 46x46x16 | |||||||||||||||
| LED indication power/ programming mode | No | Yes | No | Yes | No | Yes | ||||||||||||
| Supply voltage | 230V ±10% / 50Hz | 230V ±10% / 50Hz | 230V ±10% / 50Hz | |||||||||||||||
| Consumed power | <0.02W | <0.09W | <0.02W | <0.09W | <0.09W | |||||||||||||
| Art. nr. | 9463 | 9806 | 9794 | 9611 | 9534 | 9842 | 9779 | |||||||||||
| Smart Solutions at Home | ||||||||||||||||||